Effected by the R22 and HCFC phase out? Don’t worry, BOC can help release the pressure.
As the largest supplier of packaged refrigerants in the UK and Ireland, BOC is perfectly placed to advise you on suitable HFC retrofit replacements, including the leading ISCEON™ products such as R422D.
Indeed, now’s the perfect time to look at upgrades to your current system, whether that’s reviewing energy efficiency, taking a wider environmental outlook, or weighing up the long and short term cost implications. Not to mention future-proofing against potential future controls on HFCs.
If you are unsure of the best product to retrofit your system to, contact your HRP Service. We have all the expertise you need to advise you every step of the way.
Below are case studies that show how their performance compares with the HCFC refrigerants they have replaced.
To view the documents, you will need to download Adobe Reader.
Retrofit Products and Case Study Information
DuPont™ ISCEON® ProductsEasy-to-use, non-ozone-depleting HFC retrofit refrigerants for CFC and HCFC equipment, including the leading retrofit gas R422D.
Easy-to-use retrofit refrigerants for every application
| ISCEON® Pressure Temperature Guide | Filesize: 73kb |
R422D has emerged as the leading retrofit alternative to R22, and is being successfully used in numerous applications across a wide temperature range.
ISCEON® MO29 or R422D is an easy-to-use, non-ozone-depleting HFC refrigerant for replacing R22 in low- and medium-temperature direct expansion (DX) refrigeration applications, including commercial supermarket systems, and in stationary DX air-conditioning applications, including DX water chillers.
| ISCEON® MO29 / R422D Product Factsheet | Filesize: 17kb |
| ISCEON® MO29 / R422D Safety Datasheet | Filesize: 27kb |
| ISCEON® MO29 / R422D Pressure Enthalpy Chart | Filesize: 1.8MB |
| ISCEON® MO29 / R422D - Building Air Conditioning Case Study | Filesize: 86kb |
| ISCEON® MO29 / R422D - Stellar Group Case Study | Filesize: 1.3MB |
| ISCEON® MO29 / R422D - Banana Storage Case Study | Filesize: 177kb |
| ISCEON® MO29 / R422D - Milk Processing Case Study | Filesize: 73kb |
| ISCEON® MO29 / R422D - Restaurant Case Study | Filesize: 603kb |
| ISCEON® MO29 / R422D - REWE Supermarket Case Study | Filesize: 233kb |
| ISCEON® MO29 / R422D - Pathmark Supermarket Case Study | Filesize: 233kb |
| ISCEON® MO29 / R422D - ABCO Refrigerant Case Study | Filesize: 96kb |
| ISCEON® MO29 / R422D Retrofitting Guidelines | Filesize: 219kb |
ISCEON MO59 or R417A is an easy-to-use, non-ozone-depleting HFC retrofit refrigerant for R22 in direct expansion stationary air-conditioning (AC) and medium-temperature commercial refrigeration systems.
| ISCEON® MO59 / R417A Product Information Sheet | Filesize: 16kb |
| ISCEON® MO59 / R417A Safety Data Sheet | Filesize: 28kb |
| ISCEON® MO59 / R417A Pressure Enthalpy Chart | Filesize: 1.8MB |
| ISCEON® MO59 / R417A - Refrigeracion STARR Case Study | Filesize: 102kb |
| ISCEON® MO59 / R417A - Air Four Case Study | Filesize: 1.0MB |
ISCEON® MO79 or R422A is an easy-to-use, non-ozone-depleting HFC refrigerant for replacing R22, R502 and HCFC-containing refrigerant blends in low-temperature commercial and industrial direct expansion refrigeration systems. (Can also be used for medium temperature systems)
| ISCEON® MO79 / R422A Product Information Sheet | Filesize: 17kb |
| ISCEON® MO79 / R422A Safety Data Sheet | Filesize: 23kb |
| ISCEON® MO79 / R422A Pressure Enthalpy Chart | Filesize: 1.8MB |
| ISCEON® MO79 / R422A - IBL Cold Stores Case Study | Filesize: 123kb |
| ISCEON® MO79 / R422A Retrofit Guidelines | Filesize: 207kb |
ISCEON® MO99 (R438A) is a new retrofit refrigerant for R22 replacement, designed specifically for DX water chillers with capacity critical Thermostatic Expansion Valves. MO29 (R422D) remains the multipurpose refrigerant and gives a satisfactory performance in the majority of DX water chillers.
| ISCEON® MO99 (R438A) Product Information Sheet | Filesize: 17kb |
| ISCEON® MO99 (R438A) Retrofit Guidelines | Filesize: 418kb |
| ISCEON® MO99 / R438A Safety Data Sheet | Filesize: 32kb |
| ISCEON® MO99 / R438A Pressure Temperature Table | Filesize: 145kb |
| ISCEON® MO99 / R438A Pressure Enthalpy Diagram | Filesize: 142kb |
| ISCEON® MO99 vs ISCEON® MO29 Water Chiller Case Study | Filesize: 220kb |
RS Series Products
The RS refrigerants are non-ozone-depleting and can be used with both traditional lubricants and the new synthetic lubricants. They provide a simple and low-cost method for switching away from HCFCs.
| RS Series R22 Applications Summary | Filesize: 29kb |
| RS Series Application and PT Tables | Filesize: 50kb |
| RS Series in Water Chillers Summary | Filesize: 37kb |
Suitable for replacing R22 in air-conditioning applications across the range of equipment, and can be used in systems with a capillary as well as an expansion device. Also replaces R411B, R415A and R418A.
| RS-44 (R424A) Product Information Sheet | Filesize: 17kb |
| RS-44 (R424A) Safety Data Sheet | Filesize: 23kb |
| RS-44 (R424A) Pressure Temperature Table | Filesize: 23kb |
| RS-44 (R424A) Pressure Enthalpy Chart | Filesize: 155kb |
| RS-44 (R424A) Air Conditioning - Cable & Wireless Case Study | Filesize: 119kb |
| RS-44 (R424A) Air Conditioning - Kincore Holdings Case Study | Filesize: 135kb |
| RS-44 (R424A) Heat Pump Trial | Filesize: 32kb |
| RS-44 (R424A) Walk-In Cooler Trial | Filesize: 34kb |
| RS-44 (R424A) Window Air Conditioner Trial | Filesize: 29kb |
| RS-44 (R424A) Walk-In Cooler, Canada Trial | Filesize: 34kb |
Potential option for OEMs and can also be used to replace R22 across the range of applications and temperatures including air-conditioning and low-temperature refrigeration. RS-45 is a capacity match for R22 but should not be used in systems with a capillary.
| RS-45 (R434A) Product Information Sheet | Filesize: 17kb |
| RS-45 (R434A) Safety Data Sheet | Filesize: 27kb |
| RS-45 (R434) Pressure Temperature Table | Filesize: 19kb |
| RS-45 (R434) Pressure Enthalphy Chart | Filesize: 36kb |
| RS-45 (R434A) Flooded Chiller, British Energy, UK | Filesize: 80kb |
| RS-45 (R434A) Huike Trial Results | Filesize: 7kb |
Essentially, RS-52 is similar to R507 in its performance, has similar pressures and is near azeotropic with a glide of <1 degree centrigrade. RS-52 has been designed as a replacement for R502 and the interim ozone-depleting blends (e.g. R402A, R408A, R403B etc.), but it is also an excellent replacement for R22 at low temperatures where the system is designed to withstand R502 pressures.
| RS-52 (R428A) Product Information Sheet | Filesize: 17kb |
| RS-52 (R428A) Safety Data Sheet | Filesize: 27kb |
| RS-52 (R428A) Pressure Temperature Table | Filesize: 27kb |
| RS-52 (R428A) Pressure Enthalpy Chart | Filesize: 52kb |
| RS-52 (R428A) Trial | Filesize: 42kb |
Arkema Products - Forane® R427AForane® R427A is a non-toxic, non-flammable zero-ODP refrigerant
Forane® R427A is a 100% HFC blend. It is consequently compatible with polyol ester (POE) oil. However one characteristic of Forane® 427A is to tolerate a high residual amount of original oil in the POE lubricant (good oil return up to 10-15% residual AB or mineral oil), which allows the simplified retrofit procedure.
Forane® R427A only requires one oil draining and its replacement by a POE lubricant.
Optimal performance close to R22 can be achieved without long and costly rinsing process of the circuit thanks to a high tolerance toward residual original oil (mineral or alkylbenzene).
No modification of the installation is required.
Forane® R427A is a simplified retrofit solution for R22 existing direct expansion installations in a large range of applications. It can be used to retrofit low-temperature refrigeration equipment as well as air-conditioning installations.
| Arkema's Forane® 427A Presentation | Filesize: 3.0MB |
| Arkema's Forane® 427A Pressure Temperature Chart | Filesize: 194kb |
| Arkema's Forane® R427A Liquid Chiller Case Study | Filesize: 455kb |
| Arkema's Forane® R427A Supermarket Case Study | Filesize: 642kb |
| Arkema's Forane® R427A Water Chiller Case Study | Filesize: 560kb |
| Arkema's Forane® R427A Biscuit Factory Case Study | Filesize: 261kb |
The information on this website is furnished free of charge and is based on the technical data provided by BOC's suppliers which is believed to be reliable at the time it was provided. It is intended for use by persons having the appropriate technical skill, at their own discretion and risk. Because conditions of product use are outside our control, we make no warranties, expressed or implied, and assume no liability in connection with any use of this information. For technical support please refer to BOC or HRP prior to use.